搜索EN標準 EN 標準
輸入EN標準號,如“EN12345”并點擊搜索
C. RADIANT HEAT
Tested at a heat flux density of 20 kw/m2, garments which are claimed to offer protection against radiant heat shall meet at least performance level c1 in the following table:
PERFORMANCE LEVEL |
RHTI 24(s) |
MIN |
MAX |
C1 |
7.0 |
< 20.0 |
C2 |
20.0 |
< 50.0 |
C3 |
50.0 |
< 95.0 |
C4 |
95.0 |
|
D. MOLTEN ALUMINIUM SPLASHES
Garments which are claimed to offer protection against molten aluminium splashes shall meet at least performance level d1 in the following table:
PERFORMANCE LEVEL |
MOLTEN ALUMINIUM |
MIN |
MAX |
D1 |
100 |
< 200 |
D2 |
200 |
< 350 |
D3 |
350 |
|
E. MOLTEN IRON SPLASHES
Garments which are claimed to offer protection against molten iron splashes shall meet at least performance level e1 in the following table:
PERFORMANCE LEVEL |
MOLTEN IRON |
MIN |
MAX |
E1 |
60 |
< 120 |
E2 |
120 |
< 200 |
E3 |
200 |
|
F. CONTACT HEAT
When tested at a temperature of 250oc, garments which are claimed to offer protection against contact heat shall meet at least performance level f1 in the following table:
PERFORMANCE LEVEL |
THRESHOLD TIME (S) |
MIN |
MAX |
F1 |
5.0 |
< 10.0 |
F2 |
10.0 |
< 15.0 |
F3 |
15.0 |
|
">
EN 11612
f
EN 11611f
EN 469f
EN 1486f
EN 1149f
EN 1082-1f
EN 1073-2f
EN 943 TYPE 1_2f
EN 511f
EN 510f
EN 388f
EN 17249f
EN 381-11f
EN 381-5f
EN 381-7f
EN 342f
EN 343f
CEI EN 61482f